Refrigerated haulage operations: from booking to POD

Short answer: In refrigerated haulage every order must carry the required temperature (setpoint), and the job must keep records of measured temperature, handover and exceptions through to the POD. Transport software organises this data; the sensors and the reefer unit remain part of your equipment or your subcontractor's.

How a reefer job runs

Use cases by stage:

  • Booking: setpoint, accepted range, pre-cooling required, goods type
  • Loading: goods and trailer temperature at handover, noted on the document
  • On the road: measured temperature from the available source (unit, logger, telematics)
  • Exception: deviation from the range, dispatch and customer notified, action recorded
  • Delivery: temperature at unloading, CMR remarks, POD and temperature extract attached

Setpoint vs measured temperature

The setpoint is the value required on the order and set on the unit. Measured temperature is what the sensor records. The gap, how long a deviation lasted and where the sensor sits (return air, supply air, product) all matter in a claim.

Carrier and subcontractor responsibility

When the job is subcontracted, the carrier order must repeat the setpoint, the range and the requirement to hand over the temperature extract. Exact responsibility follows from the contracts, the CMR and the applicable law.

Limits

TransLogic One is not presented here as a native cold-chain sensor system, a validated pharmaceutical solution or reefer hardware. Access to temperature data depends on the equipment, the telematics provider and the integration, which are validated case by case.

Questions for your software and telematics supplier
TopicWhat to askWhy
Sensor coverageWhich trailers and units send temperature, and how often?Data gaps weaken your evidence
PermissionsWho sees the data: dispatch, customer, subcontractor?Customers may ask for controlled access
ExportCan you export history per job (PDF, CSV)?Needed for claims and audits
AlertsWho gets the deviation alert and how is the action recorded?Shows a timely response
SubcontractorsHow do you get data from trucks you do not own?Subcontracted jobs use other sources

Checklist for a reefer job

  • Setpoint and range on the order and on the subcontract order
  • Temperature at loading and at unloading recorded
  • The temperature data source known for that trailer
  • Exceptions recorded with time, action and person
  • Temperature extract attached to the POD

Relevant TransLogic One modules

Solutions by customer profile

Read next

All resources · Request a demo · +40 773 547 197 · office@translogicone.com

Frequently asked questions

Which records should a refrigerated job keep?

The setpoint and range from the order, temperature at loading and unloading, measured temperature history, exceptions and actions, plus the POD.

Does TransLogic One have its own temperature sensors?

We do not present native sensors. Temperature data comes from existing equipment or telematics, and the integration is validated case by case.

What should I ask a supplier about temperature data?

Sensor coverage, frequency, who has access, how history is exported per job and how you receive data from subcontractors.